Real Time Continuous Water Quality Monitoring Stations.

Parameter Varthur Lake
2022-06-29 18:45:00
Bellandhur Lake
2022-06-29 18:45:00
Agara Lake
2022-06-17 17:00:00
Units Limit
pH 7.07 6.51 6.8 pH 6.5-9.0
Temperature 26.6 25.4 27.2 °C
Dissolved Ammonia 6.17 15.26 4.5 mg/l
COD 773.94 452.16 322.63 mg/l <50
BOD 1183.29 157.94 165.52 mg/l <10
Dissolved Oxygen 0.37 0.54 3.95 mg/l
Turbidity 44.38 62.34 53.0 NTU
Conductivity 758.0 891.0 750.0 μS/cm
Chloride 424.94 123.89 15.2 mg/l
Nitrate 47.95 18.99 16.0 mg/l <10
TOC 1648.92 399.61 338.6 mg/l
Level 1.3 0.2 2.6 m
PRIMARY WATER QUALITY CRITERIA
CLASS OF WATER
DESIGNED BEST USE
A Drinking Water Source without Conventional treatment but after disinfection
B Outdoor Bathing (Organized)
C Drinking Water Source after Conventional treatment and disinfection
D Propogation of Wild Life, Fisheries
E Irrigation, Industrial Cooling, Controlled waste disposal
Below-E Not meeting A,B,C,D & E Criteria